Products Details
                    
                
                
               ICU monitor    12.1 "Standard 5 Parameters    ECG, NIBP,SpO2,RESP, TEMP,HR         Features &Benefits:    1.        10.4”,12.1”,15” color TFT display,    2.        Separated para board: ECG, NIBP, SpO2 board;    3.        Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.    4.        Real time S-T segment analysis, Drug Dose Calculation and ARR analysis;    5.        SpO2 Pitch Tone Variation and Drug Dose Calculation;    6.        Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic    7.        Parameter waveform and characters color selectable    8.        Standby mode for Energy saving and suspend monitoring;    9.        7-lead ECG waveforms display in phase;    10.    Capture dynamic waveforms;    11.    Internal storage: 3600s full-disclosure waveform review;    12.    External storage: SD card slot enables memory extension;    13.    Built-in rechargeable lithium battery, and battery volume checking,    14.    AC power checking    15.    Efficient resistance to interference of defibrillator and HF knife;    16.    SINNOR F-6 SpO2 technology, VS Nellcor accuracy;    17.    Networking capacity and TCP/IP networking platform enable abundant future upgrade    18.    Time delay switch-off function keep the monitor data restart monitor;    19.    Complete and flexible mounting solution for transportation and in-patient monitoring         Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.    Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,         Performance Specifications    Display:                          color TFT, 15”, Resolution:1024×768,    12”, 10.4” Resolution:1024×768,    Multi display selectable including:    Large-font display    Trend coexist display    OxyCRG dynamic view display.    Bed-to-bed view display    Trace:                8 waveforms(7 ECG, 1 SPO2 and 1 RESP)    Sweep speed:12.5mm/s,25mm/s,50mm/s    Indicator:             Power/battery indicator light    QRS beep and alarm sound    Battery:               Rechargeable lead acid cell, 12v/4AH    Max.24 hour for charging, 4 hours for continue working    Trend:             Parameter graphic and tabular trends:    5s/piece,8 hours;    1min/piece,168 hours(24h×7days)    5min/piece,1000 hours.         Storage:            NIBP: 1000 groups    Alarm: 200 groups    Full disclosure waveforms: 1 hour    Alarm:                    User-adjustable High, Medium and Low limits 3-level Audible and visual alarm    Networking:         Connected to central monitoring system    TCP/IP netting platform    Recorder:              Build-in, thermal array    Plethysmogram caveform:2 channels    Record mode: manual, on alarm, time-defined    Recording width: 50mm    Printing speed: 50mm/s    Recording type:         Frozen waveform record    NIBP recall record    Trend table record    Alarm record    Fixed -time record              Specifications         ECG:         Lead mode:                                5 –lead(R,L,F,N,C)    Lead selection :                        I,II,III,avR,avL,avF,V    Waveform:                          3 and 7 channel selectable    Gain selection:                        0.5mm/mv,1mm/mv,2mm/mv    Sweep speed:                          12.5mm/s;25mm/s;50mm/s    Heart rate range:               Adult: 15~300bpm;    Neonate:/pediatric:15~350bpm    Accuracy:                                   +1bpm or +1%,whichecer is greater    Resolution:                          1bpm    Filter:                                            surgery mode:1~20Hz    monitor model:0.5~40Hz    Diagnostic mode:0.05~130Hz    Scaling signal:                          1mv,+3%    Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation    Alarm range:                            15~350bpm    S-T segment detecton:    Measurement range:  2.0mV~+2.0mV         Alarm  Range:         -2.0mV~ +2.0mV    Accuracy:            -0.8mV ~+0.8Mv    Error:               +0.02Mv         Arrhythmia analysis:     YES         SPO2    Measurement range:        0~100%    Resolution:                1%    Accuracy:                 +2%(70-100%);0-69% unspecified    Alarm range               0~100%    Pluse Rate:                range:20~300bpm    Resolution:1bpm    Error:+1bpm or +2%,whichever is greater         NIBP    Method:                   Digital Automatic oscillometric    Operation mode :           Manual/Automatic/continuous    Auto measurement time:     Adjustable(1~480min)    Measurement Unit:         mmHg/Kpa selectable    Measurement types:         Systolic, Diastolic, Mean    Measurement tange:    Range of Systolic   pressure:   Adult: 40~270mmHg    Pediatric: 40~220mmHg    Neonate: 40~135mmHg    Range of mean pressure:     Adult: 20~235mmHg    Pediatric: 20~165mmHg    Neonate: 20~110mmHg    Range of diastolic pressure:   Adult: 10~215mmHg    Pediatric: 10~150mmHg    Neonate :10~100mmHg    Over-pressure protection:     Double safety protection    Resolution:                 1 mmHg    Alarm:                    Systolic.Diastolic,Mean              RESPIRATION    Method:                     Thoracic impedance    Measurement range:           Adult:7~120rpm;    Neonate/Pediatric:7~150rpm    Apnea alarm:                 YES,10~40s    Resolution:                   1rpm    Accuracy:                    +2rpm              TEMPERATURE    Compatible probe:             YSI or CYF    Measurement range:           5~50℃    Resolution :                   0.1℃    Accuracy:                    +0.1℃    Refreshing time:               about 1    Average measuring time:        <10s              Miscellaneous         Satety:                  Safety level: Class I, type CF         Dimendion and Weight    Dimendion:      440×430×450    G.Weight:        <9.0KS         Operation Environment    Temperature:    Working 0~+40℃    Transportation and storage –20~+60℃    Humidity:       working≤85%    Transportation and storage≤93%    Power:          AC 100-240,50/60Hz    Patient range:    Neonate,pediatric,and adult patients              Accessories supplies    (1) 5 lead ECG cable    (2) 1 spo2 probes    (3) 1 NIBP prbe    (4) 1 temp probe    (5)1 ground connecting liner    (6) Chest electrode (10pcs/set)              
              
                
                
                 
                                         Abs Medical Treatment Cart, 
                            
Oxygen Generator, 
                            
Operating Bed, 
                            
Collapsible Stretcher, 
                            
obstetric bed, 
                            
Portable Ot Light, 
                            
Ot Light, 
                            
Types Of Autoclave, 
                            
surgical splint price, 
                            
Medical Hospital Bed,