Products Details
ICU monitor 12.1 "Standard 5 Parameters ECG, NIBP,SpO2,RESP, TEMP,HR Features &Benefits: 1. 10.4”,12.1”,15” color TFT display, 2. Separated para board: ECG, NIBP, SpO2 board; 3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. 4. Real time S-T segment analysis, Drug Dose Calculation and ARR analysis; 5. SpO2 Pitch Tone Variation and Drug Dose Calculation; 6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic 7. Parameter waveform and characters color selectable 8. Standby mode for Energy saving and suspend monitoring; 9. 7-lead ECG waveforms display in phase; 10. Capture dynamic waveforms; 11. Internal storage: 3600s full-disclosure waveform review; 12. External storage: SD card slot enables memory extension; 13. Built-in rechargeable lithium battery, and battery volume checking, 14. AC power checking 15. Efficient resistance to interference of defibrillator and HF knife; 16. SINNOR F-6 SpO2 technology, VS Nellcor accuracy; 17. Networking capacity and TCP/IP networking platform enable abundant future upgrade 18. Time delay switch-off function keep the monitor data restart monitor; 19. Complete and flexible mounting solution for transportation and in-patient monitoring Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, Performance Specifications Display: color TFT, 15”, Resolution:1024×768, 12”, 10.4” Resolution:1024×768, Multi display selectable including: Large-font display Trend coexist display OxyCRG dynamic view display. Bed-to-bed view display Trace: 8 waveforms(7 ECG, 1 SPO2 and 1 RESP) Sweep speed:12.5mm/s,25mm/s,50mm/s Indicator: Power/battery indicator light QRS beep and alarm sound Battery: Rechargeable lead acid cell, 12v/4AH Max.24 hour for charging, 4 hours for continue working Trend: Parameter graphic and tabular trends: 5s/piece,8 hours; 1min/piece,168 hours(24h×7days) 5min/piece,1000 hours. Storage: NIBP: 1000 groups Alarm: 200 groups Full disclosure waveforms: 1 hour Alarm: User-adjustable High, Medium and Low limits 3-level Audible and visual alarm Networking: Connected to central monitoring system TCP/IP netting platform Recorder: Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined Recording width: 50mm Printing speed: 50mm/s Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record Specifications ECG: Lead mode: 5 –lead(R,L,F,N,C) Lead selection : I,II,III,avR,avL,avF,V Waveform: 3 and 7 channel selectable Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 12.5mm/s;25mm/s;50mm/s Heart rate range: Adult: 15~300bpm; Neonate:/pediatric:15~350bpm Accuracy: +1bpm or +1%,whichecer is greater Resolution: 1bpm Filter: surgery mode:1~20Hz monitor model:0.5~40Hz Diagnostic mode:0.05~130Hz Scaling signal: 1mv,+3% Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detecton: Measurement range: 2.0mV~+2.0mV Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv Error: +0.02Mv Arrhythmia analysis: YES SPO2 Measurement range: 0~100% Resolution: 1% Accuracy: +2%(70-100%);0-69% unspecified Alarm range 0~100% Pluse Rate: range:20~300bpm Resolution:1bpm Error:+1bpm or +2%,whichever is greater NIBP Method: Digital Automatic oscillometric Operation mode : Manual/Automatic/continuous Auto measurement time: Adjustable(1~480min) Measurement Unit: mmHg/Kpa selectable Measurement types: Systolic, Diastolic, Mean Measurement tange: Range of Systolic pressure: Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate :10~100mmHg Over-pressure protection: Double safety protection Resolution: 1 mmHg Alarm: Systolic.Diastolic,Mean RESPIRATION Method: Thoracic impedance Measurement range: Adult:7~120rpm; Neonate/Pediatric:7~150rpm Apnea alarm: YES,10~40s Resolution: 1rpm Accuracy: +2rpm TEMPERATURE Compatible probe: YSI or CYF Measurement range: 5~50℃ Resolution : 0.1℃ Accuracy: +0.1℃ Refreshing time: about 1 Average measuring time: <10s Miscellaneous Satety: Safety level: Class I, type CF Dimendion and Weight Dimendion: 440×430×450 G.Weight: <9.0KS Operation Environment Temperature: Working 0~+40℃ Transportation and storage –20~+60℃ Humidity: working≤85% Transportation and storage≤93% Power: AC 100-240,50/60Hz Patient range: Neonate,pediatric,and adult patients Accessories supplies (1) 5 lead ECG cable (2) 1 spo2 probes (3) 1 NIBP prbe (4) 1 temp probe (5)1 ground connecting liner (6) Chest electrode (10pcs/set)
Gyn Exam Tables For Sale,
Hospital Bed Manufacturer,
Hospital Crash Stretcher,
Luxurious Blood Donation Chair,
Ambulance Gurney,
Hospital Chair,
Portable Oxygen,
Crank Metal Hospital Bed,
Laboratory Autoclave Manufacturers,
Fast Delivery Beds,