SP-50F6-H Big Medical Syringe Infusion Pump

Best selling Syringe Pump with competitive prices Infusion pumps are in widespread use in clinical settings such as hospitals, nursing homes, and in the home.  

Products Details

Technical parameters:  
Parameter
Syringe Size 5ml, 10ml, 20ml, 30ml, 50ml ( optional: 1/2/3mL )
Flow Rate 0.0-150ml/h (0.1ml/h increment)                               5ml syringe0.0-300ml/h (0.1ml/h increment)                               10ml syringe0.0-600ml/h (0.1ml/h increment)                               20ml syringe0.0-900ml/h (0.1ml/h increment)                               30ml syringe 0.0-1200ml/h (0.1ml/h increment,1ml/h increment if over 1000ml/h)  50ml syringe
Precision ≤±2%(mechanism≤±1%)
Inquiry of total volume 0.0ml-9999ml(0.1ml increment, 1ml increment if over 1000ml)
VTBI 0.0ml-9999ml(0.1ml increment, 1ml increment if over 1000ml)
Occlusion Value High(H):800±200mmHg  (106.7±26.7kPa)Centre(C):500±100mmHg (66.7±13.3kPa)Low(L):300±100mmHg   (40.7±13.3kPa)
Alarm Remind alarm,Occlusion alarm,Near empty alarm, Empty alarm, syringe barrel unlock alarm,syringe plunger disengage alarm, syringe flange disengage alarm, AC power failure, Low battery alarm,Battery empty alarm, VTBI finish reminder, infusion tube disconnect(option)
Power AC:100V-240V±10%, 50Hz-60Hz±1HzBuilt-in Battery:DC15V Ni-MH battery. Built-in battery can run for 10 hours at 5ml/h.(It can be replaced by lithium ion battery pack if necessary.)DC:DC15V,vehicle power
Running Environment Temperature:+5℃-+40℃Relative Humidity:20%-90%Atmosphere Pressure:860hPa-1060hPa
Transport AndStorage Environment Temperature:-20℃-+55℃Relative Humidity:10%-93%Atmosphere Pressure:500hPa-1060hPa
Electric Safety Classification Class I, CF type,Built-in battery,Continuous operation equipment
Water Proof Level IPX4
Net Weight 3.5kg(include fastener)
Dimension 320mm(W)× 193mm(H)× 138mm(D)
Function
KVO rateSafety lock for PURGE/BOLUSAll brands of syringes are availablePreset occlusion detection pressure level Preset Volume To Be Infused Dual channel RS232 interface 4500 history log Standby functionSafety lock for flow rate adjustAutomatic syringe size detectionBolus release Inquiry of total infused volume Power indicator Vehicle Power Double CPU
Advanced Function
Adjust occlusion detection pressureAdjust KVO ratePreset maximum limit amount of single bolusPreset volume of alarm voice Calibrate parameter of syringePreset residual amount of solutionPreset maximum value of flow ratePreset system time

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours